Jump to content

Search the Community

Showing results for tags 'Lab3'.



More search options

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • ANNOUNCEMENTS
    • ANNOUNCEMENTS
  • CERTIFICATION - - - - - NO REQUESTS IN THESE FORUMS - - - - -
    • CISCO SYSTEMS
    • COMPTIA
    • LINUX
    • MICROSOFT
    • ORACLE
    • PROJECT MANAGEMENT
    • SECURITY CERTIFICATIONS
    • SUN MICROSYSTEMS
    • WIRELESS
    • OTHER CERTIFICATIONS
  • CISCO TECHNICAL SECTION
    • CISCO LABS
    • GNS3
    • NETWORK INFRASTRUCTURE
    • SECURITY
    • WIRELESS
    • SERVICE PROVIDERS
    • COLLABORATION, VOICE AND VIDEO
    • DATA CENTER
    • SMALL BUSINESS
  • MICROSOFT TECHNICAL SECTION
  • OTHER TECHNICAL SECTION
  • TRAINING OFFERS & REQUESTS
  • CERTCOLLECTION MALL
  • GENERAL FORUMS
  • COMMUNITY CENTER

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


AIM


MSN


Website URL


ICQ


Yahoo


Jabber


Skype


Location


Interests

Found 3 results

  1. Can anyone share latest valid CSL for CCIE security lab3, and If anyone passed lab3 please share the right answers.
  2. Is not the first time, but something is happening between mi VDC and N5K-2, the vfc 12 is not working!!! VSAN 200 stay in Initializing and after some minutes pass to isolated state: DC2-N5K-2(config)# sh vsan 200 vsan 200 information name:VSAN0200 state:active interoperability mode:default loadbalancing:src-id/dst-id operational state:up DC2-N5K-2(config)# sh vlan fcoe Original VLAN ID Translated VSAN ID Association State ---------------- ------------------ ----------------- 200 200 Operational DC2-N5K-2(config)# sh run int po 12 interface port-channel12 switchport mode trunk switchport trunk allowed vlan 200 speed 10000 DC2-N5K-2(config)# sh run int vfc12 interface vfc12 bind interface port-channel12 switchport mode E switchport trunk allowed vsan 200 no shutdown ----------------------------------- DC2-N7K-2# sh vsan 200 vsan 200 information name:VSAN0200 state:active interoperability mode:default loadbalancing:src-id/dst-id/oxid operational state:up DC2-N7K-2# sh vlan fcoe Original VLAN ID Translated VSAN ID Association State ---------------- ------------------ ----------------- 100 100 Operational 108 108 Operational 200 200 Operational DC2-N7K-2# sh run int po 12 interface port-channel12 switchport switchport mode trunk switchport trunk allowed vlan 200 mtu 9216 DC2-N7K-2# sh run int vfc-12 interface vfc-po12 bind interface port-channel12 switchport mode E switchport trunk allowed vsan 200 no shutdown DC2-N7K-2# sh int vfc-12 vfc-po12 is trunking (Not all VSANs UP on the trunk) Bound interface is port-channel12 Hardware is Ethernet Port WWN is 25:1d:00:24:f7:16:66:80 Admin port mode is E, trunk mode is on snmp link state traps are enabled Port mode is TE Port vsan is 1 Speed is 20 Gbps Trunk vsans (admin allowed and active) (200) Trunk vsans (up) () Trunk vsans (isolated) (200) Trunk vsans (initializing) () 832 fcoe in packets 76252 fcoe in octets 1983 fcoe out packets 150880 fcoe out octets Interface last changed at Sun May 29 22:32:36 2016 The L2 portchannel is configured in LACP. I tried reloading the N5K and even the VDC and nothing works!!!
  3. Hi All, I am facing a weird problem, I am also to see floggi database,on DC1-MDS1. FSM is also 100% progressed, I can see that VIF path also coming. Snapshot is attached, Please share your views what could be the probable cause
×
×
  • Create New...